(0) Cart
  • No products in the cart.

6 Volt 4.5 Amp Hour VRSLA Battery (12v 7AH / 20HR) – Ideal Duck Decoy OR Moultrie Feeder Battery

6 Volt 4.5 Amp Hour VRSLA Battery (12v 7AH / 20HR) – Ideal Duck Decoy OR Moultrie Feeder Battery

$29.99

High-quality valve regulated sealed lead acid (VRSLA) batteries from Power-Sonic provide excellent value for uses including Moultrie Feeders, Duck Decoys, Computer UPS Systems, Alarm Back-Up, Garden Tractors,
Children’s Vehicles, and Many More.

If Out Of Stock Then Please CLICK HERE For Current Price & Availability

 

$29.99

Product Description

6 Volt 4.5 Amp Hour VRSLA Battery (12v 7AH / 20HR)
– Buy Direct From The NZ Distributor – CRAFTYS RODS AND GUNS

Ideal Duck Decoy OR Moultrie Feeder Battery

Manufactured by one of China’s most respected and large battery manufacturer’s comes these High Quality ‘RSO’ branded batteries.
A Quality Absorbent Glass Mat (AGM), Valve Regulated Sealed Lead Acid (VRSLA) Technology battery.
The AGM / VRSLA Technology will give Superior Performance and durability over a standard SLA Battery.

With an up to 10 years design life, these batteries comply to the most popular international standards, such as ISO9001, ISO14001, OHSAS18000, CE and UL Standards.

AGM, VRSLA Batteries will never leak if inverted, and will continue to operate even under water.

AGM or Absorbent Glass Mat
An advanced lead-acid battery that provides superior power to support the higher electrical demands.
AGM batteries feature a thin fiberglass felt that holds the electrolyte in place like a sponge.
AGM batteries are extremely resistant to vibration, are totally sealed, nonspillable and maintenance-free.

VRSLA Valve-Regulated Sealed Lead-Acid Battery
Valve-Regulated Lead-Acid Battery is more commonly known as a sealed lead-acid (SLA), gel cell, or maintenance free battery, that can be mounted in any orientation, and do not require constant maintenance.
VRSLA batteries remain under constant pressure of 1-4 psi.
This pressure helps the recombination process under which 99+% of the Hydrogen and Oxygen generated during charging are turned back into water.
REMEMBER; To prolong serviceability all batteries require regular charging and discharging which if being unused MUST be completed every 3 months minimum for warranty purposes.

SPECIFICATIONS

  • 6V 4.5A/H Long Life Battery –
  • Sealed Lead Acid Battery
  • Maintenance Free
  • Leak Spill Proof
  • Low Self Discharge Rate
  • Useable In Any Position
  • Rugged Design
  • Safety Valve Regulated
  • Lead; No., 1 with 99.994% Purity
  • Casing; ABS
  • 70mm (L) x 47mm (W) x 100mm (H) (measurements +-1mm)
  • Total Height 106 +-2mm
  • Weight 0.72kg
  • Rated Capacity – 4.5AH, (20hr, 1.75v/cell, 25°C)
  • Self Discharge
    – 3 Months 91% Remaining Capacity
    – 6 Months 82% Remaining Capacity
    – 12 Months 65% Remaining Capacity

 

CAPACITY
The capacity of a battery, expressed in ampere-hours (AH), is the total amount of electrical energy available from a fully charged cell.
Its value depends on the discharge current, the temperature during discharge, the final cut-off voltage, and the general history of the battery.

Battery Chargers CLICK HERE

Advantages of Lead Acid Batteries?
Technology progresses in the mid-1970s, researchers developed a maintenance-free lead acid battery that was able to operate in any position.
The liquid electrolyte was transformed into moistened separator and the enclosure was sealed.
In addition, safety valves were added to allow venting of gas during charge and discharge.
Nowadays, life without lead acid batteries seems implausible.
They have myriad uses and are one of the most useful batteries with the longest life cycle, the greatest energy density per pound, and the most mature recycling infrastructure of similarly priced batteries.

The lead acid battery has been used for over 140 years.
Lead acid batteries are reliable, mature secondary batteries, globally manufactured and therefore are a widely used and understood technology.
When used correctly, they are very durable and dependable.
Their self-discharge rate is among the lowest of rechargeable battery systems.
Capable of high discharge rates, the lead acid battery is able to deliver the bursts of energy that are required to start an engine or power an item.
Lead acid batteries are environmentally sound in that they are recycled at an incredibly high rate.
Today, 98% of lead acid batteries are recycled.
With low maintenance requirements, the (SLA) lead acid battery includes no memory and no electrolyte to fil.
In terms of these advantages of the lead acid battery, they are widely used by many different industries, such as, telecommunication, power systems, radio, and television systems, solar, UPS, electric vehicles, automobile, forklifts, emergency lights, etc.

Why a battery cannot be charged (fully charged)?
If a battery can not be charged, it will be due to the occurrence of Lead sulfate (PbSO4), sulfation as it is commonly called.

Generally speaking, sulfation is the prime cause of battery failure and loss of capacity especially, sulfation is a natural occurrence in all lead / acid batteries including sealed, gel-cell, and recumbent batteries.
It’s the prime cause of early battery failure and is when the sulfur in the sulfuric acid forms sulfur crystals and they attach to the lead plates and then act as an “insulation” keeping the battery from accepting a charge.
Typical chargers and even “smart or automatic chargers” can not overcome this phenomena and thus the battery is discarded as “not being able to hold a charge”.
Sulfation occurs far more readily in hot climates where batteries aren’t frequently used or kept up to voltage.

How to avoid the plate sulfation?
1. Using an extended charge, known as an equalization charge to slow-down the rate of sulfation

2. Avoid low cutoff voltage discharges
3. Recharge immediately after discharge
4. Completely charge before using
5. Please shelve the battery after it’s fully charged
Batteries must be constantly charged and discharged like your motor vehicle battery does automatically by regular use.

Does overcharging damage batteries?
OVERCHARGING is the most destructive element in a battery’s service life.

During overcharging, excessive current causes the oxides on the plates of the battery to “shed” and precipitate to the bottom of the cell and also heat the battery, thus removing water from the electrolyte.
Once removed, this material (which represents capacity) is no longer active in the battery.
In addition, the loss of water from the electrolyte may expose portions of the plates and cause the exposed areas to oxidize and become inactive, thus reducing additional capacity.
Sealed batteries are not immune from the same internal results when overcharged.
In fact, sealed recombination absorption and gel batteries are particularly sensitive to overcharging.
Once moisture is removed from the battery, it cannot be replaced.
Portions of the battery damaged due to overcharging are irretrievable.
However, if detected early, corrective adjustments to the charging device will save the undamaged portion of the battery.
Initial signs of overcharging are excessive usage of water in the battery, continuously warm batteries, or higher than normal battery voltages while under the influence of the charger. If overcharging is suspected, correct immediately. – DO NOT OVERCHARGE, this will shorten the serviceability life of any battery.

Does over-discharging damage batteries?
OVER-DISCHARGING is a problem which originates from insufficient battery capacity causing the batteries to be overworked.

Discharges deeper than 50% (in reality well below 12.0 Volts or 1.200 Specific Gravity) significantly shortens the Cycle Life of a battery without increasing the usable depth of cycle.
Infrequent or inadequate complete recharging can also cause over-discharging symptoms called SULFATION.
Despite that charging equipment is regulating back properly, over-discharging symptoms are displayed as loss of battery capacity and lower than normal specific gravity.

CHARGING
Alternators and float battery chargers including regulated photo voltaic chargers have automatic controls which taper the charge rate as the batteries come up in charge.
It should be noted that a decrease to a few amperes while charging does not mean that the batteries have been fully charged.
Battery chargers are of three types. There is the manual type, the trickle type, and the automatic switcher type.

## Manufacturers Code ## SN06004.5 ##
Distributor Warranties Apply on All ‘New’ Product, Unless Stated Otherwise.

FOR INTERNATIONAL ORDERS – WORLDWIDE DELIVERY

Yes, we ship our products worldwide, (except Prohibited Items). For order requests outside New Zealand please send an export enquiry request
(CLICK HERE) so we can quote you, along with options for shipping.

NOTE; Importation requirements – Laws vary for every country, it is YOUR RESPONSIBILITY to ensure that you can LEGALLY import the said product you want to order. Also, each specific country we export to have their own customs duties, customs vat / tax etc., and applicable additional freight and clearing charges. Please enquire with your local customs department to verify tariff heading, tariff codes, and possible import duties charges etc., that you may incur.

CRAFTYS accepts NO RESPONSIBILTY for Legality or Additional Charges for your Importation.

Reviews

There are no reviews yet.

Only logged in customers who have purchased this product may leave a review.

Modern Tea Set